Accessories for mounting
For screwing into COMPACFOAM we recommend screws with a wooden thread and a thick screw core and sharp thread, e.g. typical window frame anchors with a diameter of 6 mm or more. The screw is inserted without pre-drilling directly into COMPACFOAM screwed in. The material displaced by the core is compacted laterally in the screw hole and thus significantly increases the pull-out strength. When screwing in small diameters (<5mm) in lower material classes (CF100, CF125, CF150), the tightening torque must be limited to prevent over-tightening.
Specially designed for processing Compacfoam materials of all classes.
For circular table saws, woodworking machines, hand-held circular saws, plunge-cut saws.
Sintered highly compressed EPS | CF100 | CF125 | CF150 | CF200 | CF300 | CF400 | CF200eco | Standard | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sintered highly compressed EPS | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | Standard | ||||||
Compressive strength (N/mm2) | ||||||||||||||
for 10% compression | 1,13 | 1,64 | 1,95 | 3,53 | 5,85 | 11,03 | 2,62 | EN 826 | ||||||
for 2% compression | 0,73 | 0,81 | 0,98 | 1,93 | 3,01 | 4,31 | 1,54 | EN 826 | ||||||
Characteristic compressive strength (N/mm2) | 1,02 | 1,48 | 1,55 | 3,19 | 5,19 | 9,97 | 2,37 | EN 14358 | ||||||
Rated value of compressive strength (N/mm2) | 0,71 | 1,02 | 1,07 | 2,21 | 3,59 | 6,90 | 1,42 | |||||||
Safety factors | ym=1,3/k mod=0,9 | ym=1,5/k mod=0,9 | ||||||||||||
Calculation value for Serviceability (N/mm2) | 0,62 | 0,69 | 0,83 | 1,64 | 2,56 | 3,66 | 1,23 | |||||||
E-modulus (N/mm2) | 28,7 | 38,4 | 45,5 | 99,4 | 168,7 | 269,8 | 73 | EN 826 | ||||||
Screw extraction | ||||||||||||||
Screw extraction* ⌀ 7.5mm (N) | 837 | 919 | 1.179 | 1.875 | 2.677 | 4.047 | 1.380 | i.a. EN 14358 | ||||||
Screw cross tension* ⌀ 7.5mm (N) | 296 | 394 | 493 | 542 | 1.012 | 1.333 | 954 | i.a. EN 14358 | ||||||
Screw extraction* ⌀ 4.5mm (N) | 505 | 565 | 747 | 979 | 1.729 | 2.829 | 701 | i.a. EN 14358 | ||||||
Cross bolt tension* ⌀ 4.5mm (N) | 103 | 112 | 150 | 214 | 319 | 500 | 320 | i.a. EN 14358 | ||||||
Thermal conductivity | ||||||||||||||
Rated value (W/mK) | 0,0387 | 0,0377 | 0,0423 | 0,0459 | 0,0531 | 0,0650 | 0,045 | EN 12667 | ||||||
Water vapor diffusion resistance coefficient | ~25 | EN 12086-1 | ||||||||||||
Building material behavior in case of fire | E (B1) flame retardant | EN 13501-1, DIN 4102-1 | ||||||||||||
Max. Water absorption capacity 28 days | ~5% | EN 12087 |
* with 40 mm anchoring length
** with 1.5 mm max. head deformation, 40 mm anchoring length, 30 mm edge distance
*** 3% Long-term deformation